| DCS-J/15-27-38 |
Densons Cold Shrink Straight
Through Joints upto 38 kV (For XLPE Cable) |
|
|
"The term 'Cold Shrink' is applied to materials, which are
capable of shrinking without raising the material above the ambient
temperature of its immediate surroundings. The Cold Shrink Accessories
are supplied from the factory in a pre-expanded condition and placed
on a removable core. Removing the core when properly positioned
over the cables causes shrinking."
 |
Components :
• Semi-Conductive Tape
• Sealing Mastic
• Earthing braid
• Silicon grease
• Roll spring
• Phase Color Marking Tape
• Copper binding wire
• Cleaning tissue
• Abrasive strap
• Armour case
• Plastic glove
*Specify for lug and other components |
|
 |
| Features |
  |
 |
- Simple structure, light in weight, single body joint reduction
jointer’s expertise, easy to install.
- Anti- Tracking/ high electrical strength, unlimited shelf
life.
- Resistance to weather, UV light and salt pollution, no
explosion and fire hazard.
- The products are carefully selected compositions of raw
materials to meet the most stringent demands and compliance
to various international specifications and standards.
- Pre-engineered/inbuilt stress cone offering high stress
control properties.
|
|
 |
| Specifications |
  |
| TEST ITEMS OF COLD SHRINK
STRAIGHT THROUGH JOINTS |
 |
| TESTS |
15
KV |
| 60
Hz voltage test |
50kV,
1min, no flashover, no strike |
| Partial
discharge test |
13kV<1pc |
| Cyclic
load test |
30
cycles under 90-95° C, 17kV |
| Impulses voltage
test |
110kV no flashover,
no strike |
| 6 Hrs, 60 Hz
voltage with standing test |
35kV, no flashover,
no strike |
|
| |
27
KV |
38
KV |
| 65kV, 1min,
no flashover, no strike |
90kV, 1min,
no flashover, no strike |
| 21.5kV<1pc |
30kV<2pc |
| 30 cycles under
90-95° C, 29kV |
30 cycles under
90-95° C, 40kV |
| 150kV no flashover,
no strike |
200kV no flashover,
no strike |
| 55kV, 15 min,
no flashover, no strike |
75kV, 15 min,
no flashover, no strike |
|
| |
 |
| Ordering Information |
  |
| 15 kV 1 Core STRAIGHT
THROUGH JOINTS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 52-1/0
(25-50) |
DCSJ
15-1 X 1
Enquiry |
| 2/0-4/0
(70-120) |
DCSJ
15-1 X 2 Enquiry |
| 300-500
(150-240) |
DCSJ
15-1 X 3 Enquiry |
| 600-800
(300-400) |
DCSJ
15-1 X 4 Enquiry |
|
15
kV 3 Core STRAIGHT THROUGH JOINTS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
|
52-1/0 (25-50) |
DCSJ
15-3 X 1 Enquiry |
|
2/0-4/0 (70-120) |
DCSJ
15-3 X 2 Enquiry |
|
300-500 (150-240) |
DCSJ
15-3 X 3 Enquiry |
|
600-800 (300-400) |
DCSJ
15-3 X 4 Enquiry |
|
27 kV 1 CORE STRAIGHT THROUGH JOINTS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSJ
27-1 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSJ
27-1 X 2 Enquiry |
| 500-800
(240-400) |
DCSJ
27-1 X 3 Enquiry |
|
27 kV 3 CORE STRAIGHT THROUGH JOINTS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSJ
27-3 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSJ
27-3 X 2 Enquiry |
| 500-800
(240-400) |
DCSJ
27-3 X 3 Enquiry |
|
38 KV 1 CORE STRAIGHT THROUGH JOINTS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/.0-185
(50-95) |
DCSJ
38-1 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSJ
38-1 X 2 Enquiry |
| 500-800
(240-400) |
DCSJ
38-1 X 3 Enquiry |
|
38 KV 3 CORE STRAIGHT THROUGH JOINTS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/.0-185
(50-95) |
DCSJ
38-3 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSJ
38-3 X 2 Enquiry |
| 500-800
(240-400) |
DCSJ
38-3 X 3 Enquiry |
|
|