| DCS-I/15-27-38 |
Densons Cold Shrink Indoor Terminations upto
38 kV
For XLPE Cable |
|
|
|
"The term ' Cold Shrink' is applied to materials, which are capable
of shrinking without raising the material above the ambient temperature
of its immediate surroundings. The Cold Shrink Accessories are supplied
from the factory in a pre-expanded condition and placed on a removable
core. Removing the core when properly positioned over the cables
causes shrinking."
Components :
• Cold Shrink Insulation Tube
• Cold shrink Breakout
• Cold Shrink Sealing Tube
• Roll Spring
• Sealing Mastic
• Void Filler
• Copper Mesh
• Phase Color Marking Tape
• Semi-Conductive Tape
• Silicon Grease
• Copper Binding Wire
• Cleaning Tissue
• Abrasive Strap
• Plastic Glove
*Specify for lug and other components |
 |
| Features |
  |
 |
- It does not require heating by flaming nor special tools.
Pull out the plastic string from silicon rubber tube, the
silicon rubber will tightly shrink on the need position.
- Reliable, superior insulation & high-recovery elasticity;
we have adopted special silicon rubber, which will keep
its radial pressure permanently ensuring environmental &
electrical protection.
- Superior hermetic sealing; for cable splicing, we have
adopted triple hermetic sealing technology & silicon
rubber with hermetic & hydrophobic performance; there
will be no serious fault due to environmental cause.
- Easy/convenient installation : by enlarging the dimensions
of stress-cone, large tolerance will be permitted &
faults due to installation are reduced to a minimum.
- Wide Usage : possessing a series of superior performance
such as anti-pollution, long usage, hydrophobic, cold-withstanding
etc. The Cold Shrink accessories can be widely used in various
regions, especially suitable for high level region, cold
weather region, high-humidity region, salt-fog region &
high-polluted region etc.
|
|
 |
| Specifications |
  |
| TEST ITEMS OF COLD SHRINK INDOOR TERMINATIONS |
 |
| TESTS °/U |
15
kV |
| 60
Hz voltage test |
50kV,
1min, no flashover, no strike |
| Partial
discharge test |
13kV<1pc |
| Cyclic
load test, |
30
cycles under 90-95° C, 17kV |
| Impulses voltage
test |
110kV no flashover,
no strike |
| 6 Hrs, 60 Hz
voltage with standing test |
35kV, no flashover,
no strike |
| Humidity test
|
No any flashover,
tracking, erosion or mechanical damage occur at 300h,
11kV |
|
27 kV |
38 kV |
| 65kV, 1min,
no flashover, no strike |
90kV, 1min,
no flashover, no strike |
| 21.5kV<1pc |
30kV<2pc |
| 30 cycles under
90-95° C, 29kV |
30 cycles under
90-95° C, 40kV |
| 150kV no flashover,
no strike |
200kV no flashover,
no strike |
| 55kV, 15 min,
no flashover, no strike |
75kV, 15 min,
no flashover, no strike |
No any flashover,
tracking, erosion or mechanical damage occur at 300h,
16kV |
No any flashover,
tracking, erosion or mechanical damage occur at 300h,
26kV |
|
 |
| Ordering Information |
  |

15 kV 1 CORE INDOOR TERMINATION |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 52-1/0
(25-50) |
DCSI
15-1 X 1
Enquiry |
| 2/0-4/0
(70-120) |
DCSI
15-1 X 2 Enquiry |
| 300-500
(150-240) |
DCSI
15-1 X 3 Enquiry |
| 600-800
(300-400) |
DCSI
15-1 X 4 Enquiry |
|
15 kV 3 Core Indoor Termination
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
|
52-1/0 (25-50) |
DCSI
15-3 X 1 Enquiry |
|
2/0-4/0 (70-120) |
DCSI
15-3 X 2 Enquiry |
|
300-500 (150-240) |
DCSI
15-3 X 3 Enquiry |
|
600-800 (300-400) |
DCSI
15-3 X 4 Enquiry |
|
27 kV 1 CORE INDOOR TERMINATION |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
|
1/0-185 (50-95)
|
DCSI
27 -1 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSI
27-1 X 2 Enquiry |
| 500-800
(240-400) |
DCSI
27-1 X 3 Enquiry |
|
27 kV 3 CORE INDOOR TERMINATION
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSI
27 -3 X 1
Enquiry |
| 4/0-400
(120-185) |
DCSI
27-3 X 2
Enquiry |
| 500-800
(240-400) |
DCSI
27-3 X 3
Enquiry |
|
|
38 kV 1 CORE INDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
| 1/0-185
(50-95) |
DCSI
38-1 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSI
38-1 X 2 Enquiry |
| 500-800
(240-400) |
DCSI
38-1 X 3 Enquiry |
|
38 kV 1 CORE INDOOR TERMINATIONS |
| Cable
Cross Section AWG/MCM (mm²) |
Type
No. |
|
1/0-185 (50-95)
|
DCSI
38-3 X 1 Enquiry |
| 4/0-400
(120-185) |
DCSI
38-3 X 2 Enquiry |
| 500-800
(240-400) |
DCSI
38-3 X 3 Enquiry |
|
|